Accumulated axial growth observed during a 6-year clinical trial of a dual focus myopia control contact lens was used to explore different approaches to assess treatment efficacy.
Axial length measurements from 170 eyes in a 6-year clinical trial of a dual focus myopia control lens (MiSight 1 day, CooperVision) were analysed. Treatment groups comprised one having undergone 6 years of treatment and the other (the initial control group) having 3 years of treatment after 3 years of wearing a single vision control lens. Efficacy was assessed by comparing accumulated ocular growth during treatment to that expected of untreated myopic and emmetropic eyes. The impact of treatment on delaying axial growth was quantified by comparing the increased time required to reach criterion growths for treated eyes and survivor analysis approaches.
When compared to the predicted accumulated growth of untreated eyes, 6 years of treatment reduced growth by 0.52 mm, while 3 years of treatment initiated 3 years later reduced growth by 0.19 mm. Accumulated differences between the growth of treated and untreated myopic eyes ranged between 67% and 52% of the untreated myopic growth, and between 112% and 86% of the predicted difference in growth between untreated myopic and age-matched emmetropic eyes. Treated eyes took almost 4 years longer to reach their final accumulated growth than untreated eyes. Treatment increased the time to reach criterion growths by 2.3-2.7 times.
Estimated growth of age-matched emmetropic and untreated myopic eyes provided evidence of an accumulated slowing in axial elongation of 0.52 mm over 6 years, and the treated growth remained close to that expected of emmetropic eyes. Six years of dual focus myopia control delayed the time to reach the final growth level by almost 4 years.
© 2023 CooperVision R&D. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.