Randomized clinical trials have failed to show benefit from increasing intensity of renal replacement therapy (RRT) but continue to be frequently used. In addition, intensive RRT is associated with an increase in adverse events potentially secondary to small solute losses, such as phosphate. We hypothesized that, compared with less-intensive RRT, intensive RRT would lead to longer duration of mechanical ventilation.
Does more-intensive renal replacement therapy in critically ill patients with acute kidney injury increase time to extubation from mechanical ventilation when compared with less-intensive therapy?
The Acute Renal Failure Trial Network study was a randomized multicenter trial of more-intensive (hemodialysis or sustained low-efficiency dialysis six times per week or continuous venovenous hemodiafiltration at 35 mL/kg per hour) vs less-intensive (hemodialysis or sustained low-efficiency dialysis three times per week or continuous venovenous hemodiafiltration at 20 mL/kg per hour) RRT in critically ill patients with acute kidney injury. Of 1124 patients, 907 who were supported by mechanical ventilation on study initiation were included in this Cox-proportional hazards analysis. The primary outcome was the time to first successful extubation off mechanical ventilation.
Patients who were assigned randomly to more-intensive RRT had a 33.3% lower hazard rate of successful extubation (hazard ratio, 0.67; 95% CI, 0.52-0.88; P < .001) when compared with patients who were assigned randomly to less-intensive RRT. Patients who were assigned randomly to more-intensive RRT had, on average, 2.07 ventilator-free days, compared with 3.08 days in those who were assigned randomly to less-intensive RRT (P < .001) over 14 days from start of the study.
Critically ill mechanically ventilated patients who were assigned randomly to more-intensive RRT had longer duration of mechanical ventilation compared with those who were assigned randomly to less-intensive RRT. The reasons for this, such as excessive phosphate loss from more-intensive RRT, deserve further study to optimize the safety and effectiveness of CRRT delivery. This was a post hoc analysis of the Acute Renal Failure Trial Network study; clinical trial registration of the original trial is NCT00076219.

Published by Elsevier Inc.

Author