Advertisement

Ophthalmology General

Metabolomic Analysis in Corneal Lenticules From Contact Lens Wearers

Oct 23, 2020

The study was done to investigate the mechanisms of pathological changes in corneal stroma and the wearing time of soft contact lenses using the metabolomic method. Laser scanning confocal microscopy...

Assessment of Corneal Haze After PRK and the Effect of Sutureless Amniotic Membrane Graft by Corneal Densitometry

Oct 23, 2020

The study was done to assess whether densitometry analysis appropriately monitors the development of haze in myopic patients after photorefractive keratectomy (PRK) when compared to subjective slit-la...

Iontophoresis Corneal Cross-linking With Enhanced Fluence and Pulsed UV-A Light: 3-Year Clinical Results

Oct 23, 2020

The study was done to assess 3-year safety and efficacy of EF I-CXL in patients with progressive keratoconus. This prospective interventional pilot study included 24 eyes of 20 patients, with a mean ...

Intrastromal Lenticule Rotation for the Treatment of High Astigmatism

Oct 23, 2020

The study was done to describe the first clinical case using intrastromal lenticule rotation to surgically correct high astigmatism in an amblyopic eye. A 31-year-old woman with mixed astigmatism of ...

Refractive Changes After Corneal Stromal Filler Injection for the Correction of Hyperopia

Oct 23, 2020

The study was done to evaluate a new non-ablative and adjustable procedure for laser ablative refractive corneal surgery in hyperopia using the injection of a biocompatible liquid filler material into...

In Vivo Visualization of Rainbow Glare and Treatment With Undersurface Flap Phototherapeutic Keratectomy

Oct 23, 2020

The study was done to analyze a case of unilateral rainbow glare that required repeated undersurface photoablation using an excimer laser. A 31-year-old man with bilateral myopia of 6.50 diopters tre...

Clinical Prediction of Excessive Vault After Implantable Collamer Lens Implantation Using Ciliary Body Morphology

Oct 22, 2020

The study was done to determine the factors related to the ciliary body that are predictive of outcomes of excessive vault (> 1,000 µm) after Implantable Collamer Lens (ICL V4c; STAAR Surgical) im...

Influence of Preoperative Keratometry on Refractive Outcomes for Myopia Correction With Small Incision Lenticule Extraction

Oct 22, 2020

The study was done to evaluate the effect of preoperative keratometry on refractive outcomes after small incision lenticule extraction (SMILE) for myopia. 515 consecutive eyes that had SMILE to corre...

Outcomes Comparison Between Wavefront-Optimized and Topography-Guided PRK in Contralateral Eyes With Myopia and Myopic Astigmatism

Oct 22, 2020

The study was done to devise a comparison between TCAT and WFO photorefractive keratectomy (PRK) in fellow eyes of myopic patients. Forty-six eyes of 23 patients who underwent PRK were included. WFO ...

Refractive Predictability Using the IOLMaster 700 and Artificial Intelligence–Based IOL Power Formulas Compared to Standard Formulas

Oct 22, 2020

The study was done to investigate the accuracy of IOL power calculation formulas using SS-OCT. 410 patients and one eye from each patient were included in this study. Using optimized constants for SS...

Comparison Between Bilateral Implantation of a Trifocal IOL and Mix-and-Match Implantation of a Bifocal IOL and an Extended Depth of Focus IOL

Oct 22, 2020

The study was done to compare the clinical outcomes of mix-and-match implantation of a diffractive extended depth of focus IOL (TECNIS Symfony ZXR00; Johnson & Johnson Vision) and a diffractive bi...

Agreement Between Two Optical Biometers Based on Large Coherence Length SS-OCT and Scheimpflug Imaging/Partial Coherence Interferometry

Oct 22, 2020

The study was done to evaluate the agreement between measurements obtained with a new optical biometer (Argos; Movu Inc) using large coherence length swept-source optical coherence tomography (SS-OCT)...

Optical Performance of a Trifocal IOL and a Novel Extended Depth of Focus IOL Combined With Different Corneal Profiles

Oct 22, 2020

The study was done to assess the effect of prior myopic ablations on the optical performance of a trifocal diffractive IOL and a novel EDOF diffractive design. The novel XACT Mono-EDOF ME4 diffractiv...

European, Multicenter, Prospective, Non-comparative Clinical Evaluation of an Extended Depth of Focus Intraocular Lens

Oct 22, 2020

The study was done to evaluate clinical and safety results obtained with an extended depth of focus (EDOF) intraocular lens (IOL). In this European, multicenter, prospective, uncontrolled, interventi...

Comparison of Optical Low-Coherence Reflectometry and Swept-Source OCT–Based Biometric Devices in Dense Cataracts

Oct 22, 2020

The study was done to investigate agreement between biometric measurements obtained from the Lenstar LS 900 (Haag-Streit AG) based on OLCR and the Tomey OA-2000 (Tomey Corporation) based on SS-OCT in ...

Bilateral Keratoconus Progression: Immediate Versus Delayed Sequential Bilateral Corneal Cross-linking

Oct 22, 2020

The study was done to compare immediate sequential bilateral corneal cross-linking (CXL), wherein both eyes are treated on the same day, to delayed sequential bilateral CXL, where each eye is treated ...

In Vivo Confocal Microscopy of Stromal Lenticule Addition Keratoplasty for Advanced Keratoconus

Oct 22, 2020

The study was done to investigate the in vivo corneal microscopic changes after femtosecond laser–assisted stromal lenticule addition keratoplasty in keratoconus by means of in vivo confocal microsc...

Recommendations for the management of ocular sarcoidosis from the International Workshop on Ocular Sarcoidosis

Oct 22, 2020

The study was done to establish expert recommendations for the management of ocular sarcoidosis (OS). A question-based survey on the management of OS was circulated to international uveitis experts (...

Factors affecting central corneal thickness measurement agreement between Scheimpflug imaging and ultrasound pachymetry in keratoconus

Oct 22, 2020

This study was done for the evaluation of the agreement of central corneal thickness (CCT) measurement between Scheimpflug imaging and ultrasound (U/S) pachymetry in keratoconus eyes, and investigated...

Long-term efficacy of early infliximab-induced remission for refractory uveoretinitis associated with Behçet’s disease

Oct 22, 2020

The study was done to evaluate long-term efficacy of infliximab (IFX) in refractory uveoretinitis associated with Behçet’s disease (BD) depending on uveoretinitis duration. 16 patients with BD (32...

SUBSPECIALTIES

Advertisement